المبخرات

مبردات هواء لغرف التبريد والمستودعات.

كتالوج المنتجات

طراز
1,893
نطاق السعة
0.8 – 78.3 kW

1,893 / 1,893 طرازSC2 · 0 °C

SC3 · −18 °Cالمروحة
SNKTSB25 113 6 (PLS)TSB · 730 × 591 × 276 mm0.8 kW0.62 kW1 × Ø250787 m³/h
SNKTSB30 113 6 (PLS)TSB · 730 × 654 × 341 mm0.94 kW0.74 kW1 × Ø3001,141 m³/h
SNKTSA30 113 8 (PLS)TSA · 730 × 663 × 377 mm0.97 kW0.79 kW1 × Ø3001,327 m³/h
SNKTSB25 113 4 (PLS)TSB · 730 × 591 × 276 mm0.98 kW0.76 kW1 × Ø250732 m³/h
SNKTSB25 114 6 (PLS)TSB · 730 × 619 × 276 mm0.98 kW0.74 kW1 × Ø250747 m³/h
SNKTDB25 113 6 (PLS)TDB · 700 × 885 × 375 mm1.05 kW0.8 kW1 × Ø250910 m³/h
SNKTEH30 113 10 (PLS)TEH · 700 × 580 × 540 mm1.05 kW0.87 kW1 × Ø3001,575 m³/h
SNKTSB25 115 6 (PLS)TSB · 730 × 647 × 276 mm1.09 kW0.79 kW1 × Ø250660 m³/h
SNKTDA30 113 8TDA · 838 × 819 × 358 mm1.13 kW0.96 kW1 × Ø3001,548 m³/h
SNKTDA30 113 8 (PLS)TDA · 838 × 819 × 358 mm1.13 kW0.96 kW1 × Ø3001,548 m³/h
SNKTEA30 113 10 (PLS)TEA · 710 × 463 × 515 mm1.13 kW0.88 kW1 × Ø3001,499 m³/h
SNKTSB25 114 4 (PLS)TSB · 730 × 619 × 276 mm1.15 kW0.85 kW1 × Ø250656 m³/h
SNKTSB30 114 6 (PLS)TSB · 730 × 682 × 341 mm1.15 kW0.86 kW1 × Ø3001,020 m³/h
SNKTSB30 113 4 (PLS)TSB · 730 × 654 × 341 mm1.16 kW0.9 kW1 × Ø300835 m³/h
SNKTSA30 113 6 (PLS)TSA · 730 × 663 × 377 mm1.17 kW0.97 kW1 × Ø3001,244 m³/h
SNKTSA35 113 8 (PLS)TSA · 730 × 709 × 382 mm1.17 kW0.99 kW1 × Ø3502,042 m³/h
SNKTDA35 113 8 L (PLS)TDA · 838 × 864 × 358 mm1.18 kW1.01 kW1 × Ø3501,684 m³/h
SNKTSB25 116 6 (PLS)TSB · 730 × 674 × 276 mm1.19 kW0.94 kW1 × Ø250614 m³/h
SNKTEH30 113 8 (PLS)TEH · 700 × 580 × 540 mm1.24 kW1.04 kW1 × Ø3001,553 m³/h
SNKTSB25 115 4 (PLS)TSB · 730 × 647 × 276 mm1.24 kW0.89 kW1 × Ø250599 m³/h
SNKTEH35 113 10 (PLS)TEH · 700 × 580 × 540 mm1.26 kW1.09 kW1 × Ø3502,682 m³/h
SNKTSB30 115 6 (PLS)TSB · 730 × 710 × 341 mm1.28 kW0.92 kW1 × Ø300918 m³/h
SNKTDB30 113 6 (PLS)TDB · 738 × 778 × 350 mm1.29 kW1.03 kW1 × Ø3001,410 m³/h
SNKTEA30 113 8 (PLS)TEA · 700 × 500 × 505 mm1.29 kW1.02 kW1 × Ø3001,471 m³/h
SNKTSA30 114 8 (PLS)TSA · 730 × 698 × 377 mm1.29 kW1.04 kW1 × Ø3001,231 m³/h
SNKTDB25 113 4 (PLS)TDB · 700 × 885 × 375 mm1.32 kW1.03 kW1 × Ø250870 m³/h
SNKTSB30 114 4 (PLS)TSB · 730 × 682 × 341 mm1.35 kW0.97 kW1 × Ø300815 m³/h
SNKTDB25 114 6 (PLS)TDB · 738 × 778 × 284 mm1.36 kW1.03 kW1 × Ø250900 m³/h
SNKTSA35 113 6 (PLS)TSA · 730 × 709 × 382 mm1.37 kW1.16 kW1 × Ø3501,855 m³/h
SNKTSB25 116 4 (PLS)TSB · 730 × 674 × 276 mm1.37 kW1.08 kW1 × Ø250559 m³/h
SNKTSB35 113 4 (PLS)TSB · 730 × 683 × 394 mm1.37 kW1.37 kW1 × Ø3501,885 m³/h
SNKTEA35 113 10 (PLS)TEA · 710 × 464 × 515 mm1.39 kW1.12 kW1 × Ø3502,470 m³/h
SNKTEH30 114 10 (PLS)TEH · 700 × 580 × 540 mm1.4 kW1.14 kW1 × Ø3001,518 m³/h
SNKTSB35 113 6 (PLS)TSB · 730 × 683 × 394 mm1.4 kW1.01 kW1 × Ø3502,000 m³/h
SNKTDA30 113 6 (PLS)TDA · 700 × 885 × 335 mm1.43 kW1.19 kW1 × Ø3001,491 m³/h
SNKTSB30 116 6 (PLS)TSB · 730 × 737 × 341 mm1.43 kW1.14 kW1 × Ø300845 m³/h
SNKTSB30 115 4 (PLS)TSB · 730 × 710 × 341 mm1.44 kW0.99 kW1 × Ø300771 m³/h
SNKTEA30 114 10TEA · 710 × 463 × 515 mm1.45 kW1.11 kW1 × Ø3001,428 m³/h
SNKTEA30 114 10 (PLS)TEA · 710 × 463 × 515 mm1.45 kW1.11 kW1 × Ø3001,428 m³/h
SNKTEB30 113 6 (PLS)TEB · 710 × 463 × 563 mm1.45 kW1.14 kW1 × Ø3001,480 m³/h

حول مبخرات غرف التبريد

المبخر (مبرد الهواء) هو الوحدة الداخلية التي تحافظ على درجة حرارة غرفة التبريد بنقل حرارة الهواء إلى غاز التبريد. تُصنع مبخرات سونكار بمبادلات حرارية من أنابيب النحاس وزعانف الألومنيوم، وتغطي بأعداد وأقطار مراوح وتباعد زعانف مختلفة التطبيقات من التكييف حتى تخزين المجمدات.

اختر الطراز وفق سعة التبريد المطلوبة (كيلوواط) ودرجة حرارة الغرفة وغاز التبريد المستخدم. يقلل تباعد الزعانف الأكبر من تأثير الصقيع في التخزين منخفض الحرارة، بينما يحافظ تدفق الهواء المتوازن على المنتجات الطازجة من الجفاف.