Evaporatorlar

Soyuq otaqlar və anbarlar üçün hava soyuducuları.

Məhsul kataloqu

Model
1.893
Güc aralığı
0,8 – 78,3 kW

1.893 / 1.893 modelSC2 · 0 °C

SC3 · −18 °CFan
SNKTSB25 113 6 (PLS)TSB · 730 × 591 × 276 mm0,8 kW0,62 kW1 × Ø250787 m³/h
SNKTSB30 113 6 (PLS)TSB · 730 × 654 × 341 mm0,94 kW0,74 kW1 × Ø3001.141 m³/h
SNKTSA30 113 8 (PLS)TSA · 730 × 663 × 377 mm0,97 kW0,79 kW1 × Ø3001.327 m³/h
SNKTSB25 113 4 (PLS)TSB · 730 × 591 × 276 mm0,98 kW0,76 kW1 × Ø250732 m³/h
SNKTSB25 114 6 (PLS)TSB · 730 × 619 × 276 mm0,98 kW0,74 kW1 × Ø250747 m³/h
SNKTDB25 113 6 (PLS)TDB · 700 × 885 × 375 mm1,05 kW0,8 kW1 × Ø250910 m³/h
SNKTEH30 113 10 (PLS)TEH · 700 × 580 × 540 mm1,05 kW0,87 kW1 × Ø3001.575 m³/h
SNKTSB25 115 6 (PLS)TSB · 730 × 647 × 276 mm1,09 kW0,79 kW1 × Ø250660 m³/h
SNKTDA30 113 8TDA · 838 × 819 × 358 mm1,13 kW0,96 kW1 × Ø3001.548 m³/h
SNKTDA30 113 8 (PLS)TDA · 838 × 819 × 358 mm1,13 kW0,96 kW1 × Ø3001.548 m³/h
SNKTEA30 113 10 (PLS)TEA · 710 × 463 × 515 mm1,13 kW0,88 kW1 × Ø3001.499 m³/h
SNKTSB25 114 4 (PLS)TSB · 730 × 619 × 276 mm1,15 kW0,85 kW1 × Ø250656 m³/h
SNKTSB30 114 6 (PLS)TSB · 730 × 682 × 341 mm1,15 kW0,86 kW1 × Ø3001.020 m³/h
SNKTSB30 113 4 (PLS)TSB · 730 × 654 × 341 mm1,16 kW0,9 kW1 × Ø300835 m³/h
SNKTSA30 113 6 (PLS)TSA · 730 × 663 × 377 mm1,17 kW0,97 kW1 × Ø3001.244 m³/h
SNKTSA35 113 8 (PLS)TSA · 730 × 709 × 382 mm1,17 kW0,99 kW1 × Ø3502.042 m³/h
SNKTDA35 113 8 L (PLS)TDA · 838 × 864 × 358 mm1,18 kW1,01 kW1 × Ø3501.684 m³/h
SNKTSB25 116 6 (PLS)TSB · 730 × 674 × 276 mm1,19 kW0,94 kW1 × Ø250614 m³/h
SNKTEH30 113 8 (PLS)TEH · 700 × 580 × 540 mm1,24 kW1,04 kW1 × Ø3001.553 m³/h
SNKTSB25 115 4 (PLS)TSB · 730 × 647 × 276 mm1,24 kW0,89 kW1 × Ø250599 m³/h
SNKTEH35 113 10 (PLS)TEH · 700 × 580 × 540 mm1,26 kW1,09 kW1 × Ø3502.682 m³/h
SNKTSB30 115 6 (PLS)TSB · 730 × 710 × 341 mm1,28 kW0,92 kW1 × Ø300918 m³/h
SNKTDB30 113 6 (PLS)TDB · 738 × 778 × 350 mm1,29 kW1,03 kW1 × Ø3001.410 m³/h
SNKTEA30 113 8 (PLS)TEA · 700 × 500 × 505 mm1,29 kW1,02 kW1 × Ø3001.471 m³/h
SNKTSA30 114 8 (PLS)TSA · 730 × 698 × 377 mm1,29 kW1,04 kW1 × Ø3001.231 m³/h
SNKTDB25 113 4 (PLS)TDB · 700 × 885 × 375 mm1,32 kW1,03 kW1 × Ø250870 m³/h
SNKTSB30 114 4 (PLS)TSB · 730 × 682 × 341 mm1,35 kW0,97 kW1 × Ø300815 m³/h
SNKTDB25 114 6 (PLS)TDB · 738 × 778 × 284 mm1,36 kW1,03 kW1 × Ø250900 m³/h
SNKTSA35 113 6 (PLS)TSA · 730 × 709 × 382 mm1,37 kW1,16 kW1 × Ø3501.855 m³/h
SNKTSB25 116 4 (PLS)TSB · 730 × 674 × 276 mm1,37 kW1,08 kW1 × Ø250559 m³/h
SNKTSB35 113 4 (PLS)TSB · 730 × 683 × 394 mm1,37 kW1,37 kW1 × Ø3501.885 m³/h
SNKTEA35 113 10 (PLS)TEA · 710 × 464 × 515 mm1,39 kW1,12 kW1 × Ø3502.470 m³/h
SNKTEH30 114 10 (PLS)TEH · 700 × 580 × 540 mm1,4 kW1,14 kW1 × Ø3001.518 m³/h
SNKTSB35 113 6 (PLS)TSB · 730 × 683 × 394 mm1,4 kW1,01 kW1 × Ø3502.000 m³/h
SNKTDA30 113 6 (PLS)TDA · 700 × 885 × 335 mm1,43 kW1,19 kW1 × Ø3001.491 m³/h
SNKTSB30 116 6 (PLS)TSB · 730 × 737 × 341 mm1,43 kW1,14 kW1 × Ø300845 m³/h
SNKTSB30 115 4 (PLS)TSB · 730 × 710 × 341 mm1,44 kW0,99 kW1 × Ø300771 m³/h
SNKTEA30 114 10TEA · 710 × 463 × 515 mm1,45 kW1,11 kW1 × Ø3001.428 m³/h
SNKTEA30 114 10 (PLS)TEA · 710 × 463 × 515 mm1,45 kW1,11 kW1 × Ø3001.428 m³/h
SNKTEB30 113 6 (PLS)TEB · 710 × 463 × 563 mm1,45 kW1,14 kW1 × Ø3001.480 m³/h

Soyuq otaq evaporatorları haqqında

Evaporator (hava soyuducusu) havanın istiliyini soyuducu agentə ötürərək soyuq otağı lazımi temperaturda saxlayan daxili blokdur. Sonkar evaporatorları mis boru və alüminium lamelli istilik dəyişdiricisi ilə istehsal olunur; müxtəlif fan sayı, fan diametri və lamel aralığı ilə kondisionerdən dondurulmuş anbarlara qədər geniş tətbiq sahəsini əhatə edir.

Modeli lazım olan soyutma tutumuna (kW), otağın temperaturuna və istifadə olunan soyuducu agentə görə seçin. Aşağı temperaturlu anbarlarda buzlanmanın təsirini azaltmaq üçün geniş lamel aralıqlı modellər, təzə məhsul anbarlarında isə məhsulu qurutmayan balanslı hava axınlı modellər üstünlük təşkil edir.